Phosphorylated Tau 181 (p-Tau 181) (CLIA)
Product Detail
Product Description
The Vazyme Phosphorylated Tau 181 (p-Tau 181) CLIA Kit is designed for quantitative measurement of p-Tau 181 in plasma for Alzheimer’s disease biomarker research. It combines a double-antibody sandwich chemiluminescence immunoassay with an automated analyzer workflow.
This p-Tau 181 immunoassay uses a double-antibody sandwich chemiluminescence format. Monoclonal anti-p-Tau 181 antibodies coated on magnetic particles serve as capture antibodies, while acridinium ester-labeled monoclonal anti-p-Tau 181 antibodies serve as detection antibodies. Following the immunoreaction, pre-trigger and trigger solutions initiate chemiluminescent signal emission. The analyzer measures the resulting relative light units (RLUs), which are directly proportional to the p-Tau 181 concentration in the sample. Each kit includes one reagent cartridge, two-level quality control materials, and three-level calibrators. This product is intended for Research Use Only and is not for use in diagnostic procedures.
Features
Automated CLIA Workflow: Designed for use with compatible fully automated chemiluminescence immunoassay analyzers to support streamlined p-Tau 181 quantification in research workflows.
efined Analytical Performance: The assay has a Limit of Blank (LoB) of ≤0.50 pg/mL and a linear range of 1.00–200.00 pg/mL, with a linear correlation coefficient of r ≥0.9900.
Monoclonal Antibody-Based Detection: The assay uses monoclonal anti-p-Tau 181 antibodies for capture and detection in a double-antibody sandwich format.
Precision and Trueness Specifications: Repeatability CV is ≤8.00%, intermediate precision CV is ≤15.00%, and trueness is specified as relative deviation within −15% to +15%.
Specifications
Product details and analytical characteristics provided for the p-Tau 181 CLIA Kit.
| Product name | Phosphorylated Tau 181 (p-Tau 181) (CLIA) |
|---|---|
| Catalog number | AD003 |
| Pack size | 100 tests/kit |
| Principle | Double-antibody sandwich chemiluminescence immunoassay (CLIA) |
| Species reactivity (validated) | Human, P301S mice, non-human primate, brain organoids |
| Sample type | EDTA plasma, CSF, brain homogenate, cell culture supernatant |
| Linear range | 1.00–200.00 pg/mL |
| Linear correlation coefficient | r ≥ 0.9900 |
| Limit of Blank (LoB) | ≤ 0.50 pg/mL |
| Repeatability | CV ≤ 8.00% |
| Intermediate precision | CV ≤ 15.00% |
| Trueness | Relative deviation: −15% to +15% |
| Calibration | Three-level calibrators; lot-based calibration procedure to be confirmed |
| Quality control | Two-level QC materials included |
| Sample volume | 100 µL |
| Storage | 2–8 °C, protected from light |
| Shelf life | 12 months (subject to confirmation against the current product specification) |
| Intended use | For Research Use Only. Not for use in diagnostic procedures. |
Assay Principle
The assay uses a double-antibody sandwich format. Magnetic particles coated with monoclonal anti-p-Tau 181 antibodies capture the target analyte. Acridinium ester-labeled monoclonal anti-p-Tau 181 antibodies are used for detection. After the immunoreaction, pre-trigger and trigger solutions initiate chemiluminescent emission. The analyzer measures relative light units (RLUs), which are directly proportional to the p-Tau 181 concentration in the sample.
Visual recommendation: use a simple four-step horizontal flow: Magnetic-particle capture → p-Tau 181 binding → Acridinium-ester detection → Chemiluminescent signal measurement. The image must depict the documented method, not a generic ELISA plate workflow.
Research Applications
Applications and Intended Use
p-Tau181 is one of the most extensively characterized tau phosphorylation sites in Alzheimer's disease (AD) research. As a core component of the "T" (tau pathology) biomarker in the ATN framework, it has been validated across decades of CSF and plasma studies. However, its plasma abundance is low and subject to matrix interference, placing high demands on assay sensitivity and specificity—particularly in early-stage AD samples, where signal levels are faint and conventional platforms often fall short.
From Detecting Tau Fragments to Specifically Detecting p-Tau181
With highly specific antibody pairs and an ultrasensitive chemiluminescence platform, the Vazyme p-Tau181 assay specifically recognizes p-Tau181, reduces plasma-matrix interference, and reliably detects low-abundance p-Tau181 in plasma—supporting research into:
●Neurodegenerative disease basic & translational research
●Early AD screening
●Pathological staging
●Clinical exploratory research
●Therapeutic clinical trials
●Animal model validation, efficacy & mechanism study
●Large-cohort epidemiology & biomarker discovery
Kit Contents and Compatibility
Compatible Instruments
Automatic Chemiluminescence Immunoassay Analyzer , Model Elf S290R
Kit Contents
Our ready-to-use Phosphorylated Tau 181 (p-Tau 181) (CLIA) kits contain all the reagents necessary to run your p-Tau 181 assays. Each kit contains enough reagents for 100 tests.
| Magnetic Particle Suspension | 5.0 mL |
|---|---|
| Labeled Antibody Working Solution | 11.0 mL |
| Assay Diluent | 6.0 mL |
| Quality Control Materials | 1 set |
| Calibrators | 1 set |