Top IconTOP
VaPura 32-Automatic nucleic acids extraction instrument
< >
VaPura 32-Automatic nucleic acids extraction instrument
VaPura 32-Automatic nucleic acids extraction instrument
VaPura 32-Automatic nucleic acids extraction instrument

VaPura 32-Automatic nucleic acids extraction instrument

Size
Cat. No.
VaPura 32-Automatic nucleic acids extraction instrument
VaPura 32-Automatic nucleic acids extraction instrument
VaPura 32-Automatic nucleic acids extraction instrument
VaPura 32-Automatic nucleic acids extraction instrument
Size
Cat. No.

Product Detail

VaPura 32 Automated Nucleic Acid Extraction System

 Product Description  


VaPura 32 is a high-throughput and high-precision automated nucleic acid extraction system used together with prepackaged extraction reagents based on silica-coated superparamagnetic beads to extract and purify nucleic acids from blood, tissue, cells, body fluids, bacteria, viruses, and other biological samples.

The system purifies and enriches nucleic acids by utilizing magnetic rods to capture, transfer, and release magnetic beads. Featuring a highly automated, fast, and simple workflow, VaPura 32 is an ideal solution for molecular diagnosis and animal disease detection.


 Features  


  • Simple & Efficient Workflow

Simply add the sample and start the preset program. VaPura 32 performs fully automated nucleic acid extraction with a one-button operation.

  • High Extraction Efficiency

Recovery rate is higher than 95%, supported by strong magnetic force adsorption of magnetic beads and permanent magnet technology.

  • Effective Contamination Control

The built-in UV module and filtered fan system help reduce the risk of contamination during operation.

  • Power Failure Protection

If power is interrupted during operation, the system resumes the extraction process after restart, helping prevent sample loss caused by unexpected power failure.


 Parameters  


The technical specifications below summarize the key operating parameters of the VaPura 32 automated nucleic acid extraction system.


Parameter

VaPura 32

Principle

Magnetic Beads Method

Sample throughput

1~32

Compatible consumables

96 deep well plate

Processing volume /μL

20~1000

Difference between 

purification repeats

CV≤5%

Heating temperature

Room temperature~120℃

Temperature accuracy

±1℃

Operation interface

8-inch color touch screen,can be connected to external mouse

Internal procedures

500 programs can be stored

Program management

Add,edit,save as,delete,program mode

Instrument interface

3 type A USB,1 Ethernet port,1 DB9 debug interface

Network

Wi-Fi function

Disinfection

UV disinfection

Maximum input power

500 W

Dimensions(W×D×H)

412 mm×410 mm×430 mm

Weight(kg)

30 kg



 Storage  


Storage: 15–25°C