Top IconTOP
VAHTS Repair Module for ONT V2
< >
VAHTS Repair Module for ONT V2

VAHTS Repair Module for ONT V2

Size
Cat. No.
VAHTS Repair Module for ONT V2
VAHTS Repair Module for ONT V2
Size
Cat. No.

Product Detail

 Product Description  

The VAHTS Repair Module for ONT V2 is a module specifically optimized for Oxford Nanopore Technologies (ONT) sequencing, suitable for damage repair and end preparation of genomic DNA (gDNA) and amplicons. It combines a specifically optimized selection of high-activity mutant enzymes with a finely tuned buffer system to support efficient DNA repair and robust library preparation.

DNA Damage Repair, End Repair and dA-tailing prepare the DNA fragments for the downstream Barcode Adapter or Sequencing Adapter ligation step. The DNA Damage Repair and End Preparation functions are configured as separate modules and can be used as needed. All reagents are manufactured under rigorous quality control and functional testing.

 Features  

  • Optimized high-activity mutant enzymes: A selected combination of high-activity mutant enzymes supports efficient DNA damage repair and end preparation.

  • Optimized buffer system: End Prep Buffer and DNA Repair Buffer are tuned to the enzyme combination for consistent reaction performance.

  • Enhanced DNA repair efficiency: The repair step improves the quality of damaged DNA templates ahead of library preparation.

  • Reliable library preparation: All reagents undergo quality control and functional testing to support reproducibility of library preparation.

  • Broad ONT application compatibility: Supports single-sample and multi-sample gDNA library preparation across animals, plants, microorganisms, and other species, with workflow compatibility for Nanopore #SQK-LSK114 & #SQK-NBD114, etc.

  • Compatible with multiple instrument models: Suitable for use with all Nanopore sequencer, including MinION®, GridION®, PromethION®.

Specification  

PRODUCT IDENTITY

Parameter

Specification

Product Name

VAHTS Repair Module for ONT V2

Catalog Number

TN2025-01; TN2025-02

Pack Size

24 rxns; 96 rxns

Product Type

DNA Repair and End Preparation Module

Input DNA

Genomic DNA (gDNA) and amplicon

Technology

Optimized Mutant Enzyme System

Species

Animals, Plants, Microorganisms

FUNCTION & COMPOSITION

Parameter

Specification

Core Functions

DNA Damage Repair, End Repair, dA-tailing

DNA Damage Repair Module

DNA Repair Buffer and DNA Repair Mix

End Preparation Module

End Prep Buffer and End Prep Enzyme Mix

Buffers

End Prep Buffer, DNA Repair Buffer

Enzyme Mixes

End Prep Enzyme Mix, DNA Repair Mix

REAGENT COMPONENTS

Parameter

Specification

End Prep Buffer

84 μL (TN2025-01, 24 rxns); 336 μL (TN2025-02, 96 rxns)

DNA Repair Buffer

84 μL (TN2025-01, 24 rxns); 336 μL (TN2025-02, 96 rxns)

End Prep Enzyme Mix

72 μL (TN2025-01, 24 rxns); 288 μL (TN2025-02, 96 rxns)

DNA Repair Mix

48 μL (TN2025-01, 24 rxns); 192 μL (TN2025-02, 96 rxns)

WORKFLOW & COMPATIBILITY

Parameter

Specification

Compatible Protocols

SQK-LSK114; SQK-NBD114

Compatible Sequencers

MinION, GridION, PromethION

Single-sample Preparation

Supported

Multi-sample Preparation

Supported (workflow subject to validation)

Downstream Step

Barcode Adapter or Sequencing Adapter ligation

STORAGE & SHIPPING


Parameter

Specification

Storage

-30 ~ -15 °C

Shipping

≤0 °C


Research Applications  

  • Whole Genome Sequencing (WGS) and long-read sequencing on the ONT platform.

  • Amplicon sequencing with amplicon DNA input.

  • Animal and plant genomics research using genomic DNA.

  • Microbial genomics research using genomic DNA.

  • Nanopore DNA library preparation for single-sample and multi-sample workflows.


VAHTS Repair Module for ONT V2Working Principle  

  1. DNA Damage Repair: DNA Repair Buffer and DNA Repair Mix repair damage in the DNA sample and improve the quality of the DNA template.

  2. End Repair: The DNA ends are processed to meet the requirements of downstream adapter ligation.

  3. dA-tailing: An A base is added to the DNA ends to prepare them for compatible adapter ligation.

  4. Adapter Ligation: The repaired and end-prepared DNA enters the downstream Barcode Adapter or Sequencing Adapter ligation step.


VAHTS Repair Module for ONT V2Product Combination  

Cat. No.Product NameRole in ONT V2 workflow
TS202VAHTS TGS DNA Library Prep Kit for ONT V2Complete DNA library preparation kit (end to end)
TN2025VAHTS Repair Module for ONT V2DNA damage repair, end preparation and A-tailing
TN2026VAHTS BD Ligation Module for ONT V2Barcode Adapter ligation
TN2027VAHTS MP Ligation Module for ONT V2Motor Protein Adapter ligation
TAB20105VAHTS TGS DNA BD Adapters Set 1 - Set 4 for ONT (Plate)96 Barcode Adapters


For Research Use Only. Not for use in diagnostic procedures.